CODA (EMAT, DCUT, UT)

CODA is the first and only compact high-power UT flaw detector capable of working with both EMAT and piezoelectric sensors using Innerspec’s patented pulser technology.

APPLICATIONS

CODA
CODA+
CODA SM
Spot Measurement (EMAT, DCUT)
Standard Piezoelectric
Bolt-Load Measurement
Encoded Applications (EMAT, PIEZO)
Stress Measurement

Techniques

EMAT
PIEZO
Technique
Normal Beam
Normal, Shear, Surface
Sensors
Innerspec
UT from any manufacturer
DCUT from Innerspec
Couplant Required
NO
YES (Except DCUT Sensors)
Best For:
Extreme Temperatures, Coated and Rough Surfaces, Curved Parts
All Conventional UT Applications
Thickness Measurement
Flaw Detection (encoded)
Corrosion Mapping (encoded)
Stress Measurement
Bolt Load Measurement

Hardware OPTIONS

CODA
CODA+
CODA SM
Characteristics
1 Channel EMAT, 1 Channel UT Mux EMAT/PIEZO
1 Channel EMAT, 1 Channel UT
Mux EMAT/PIEZO
Single Axis Encoder
1 Channel EMAT, 1 Channel UT
Mux EMAT/PIEZO & EMAT/EMAT
Single Axis Encoder
Spot Measurement (EMAT, DCUT, UT)
Encoded Thickness Measurement (EMAT) and Flaw Detection (EMAT, PIEZO)
OPTIONAL
Stress Measurement for RR Wheels
OPTIONAL
Stress Measurement for Plates & Pipes
OPTIONAL
Thickness Grid
OPTIONAL
OPTIONAL
OPTIONAL
Bolt Load Single (EMAT)
OPTIONAL
OPTIONAL
OPTIONAL
Bolt Load Double (EMAT+PIEZO)
OPTIONAL
OPTIONAL
OPTIONAL

Software

ITOP with NDT-WEB

CODA uses Innerspec Technologies Operating Platform (ITOP) with NDT-WEB application software. Innerspec’s NDT-WEB technology permits accessing and operating the instrument from any phone, tablet, laptop or desktop directly from a web browser, independently of the device’s Operating System, and without having to install potentially unsafe files or apps. Connection to CODA is immediate through the built-in WiFi and/ Ethernet port.

Sensors

A variety of sensors and accessories to optimize performance in the most challenging environments.

CODA can be used with 20+ EMAT sensors and DCUT sensors from Innerspec and conventional piezoelectric sensors from any manufacturer.

Innerspec’s EMAT and DCUT sensors in combination with scanners, positioners and other accessories have been designed to inspect a wide range of materials in harsh, industrial settings.

Check our Catalog of Standard EMAT & DCUT Sensors and Accessories HERE or Contact Us for your unique needs.

SPECIFICATIONS

CODA – Technical Specifications
Ultrasonic Pulsers 1 - EMAT 1 - PIEZO
Bandwidth 1500 kHz to 10 MHz 100 kHz to 10 MHz
Pulse Repetition Rate Up to 400 Hz Up to 400 Hz
RF Pulser 1-3 Cycles (Toneburst)
16kW power output
800Vpp @ 40Amp pk
0.6% maximum duty
Half Cycle Square Wave
600 W Power Output
100 V - 400 V @ 5Amp pk
0.6% Maximum Duty
Receivers 20 dB to 90 dB Gain 0 dB to 48 dB Gain
Pulse / Receive Modes Pulse-Echo/Pitch-Catch
Dual Channel Multiplexer Yes (CODA SM) No
Analog /Digital Converters 14-bit, 100 MSPS
Rectification Full-wave +/- half-wave, Envelope and RF mode
Filtering Programmable digital filters
Evaluation Gates 3 gates per channel
Amplitude, time and frequency
Encoder Interface A/B Quadrature or clock/direction (CODA+, CODA SM)
PC Communication Wi-Fi 2x802.11ac/ax dual band
USB 3.0, Ethernet
Software ITOP with NDT-WEB
Internal Storage Capacity 32 GB SSD
Memory 8 GB RAM
Probe Connector LEMO, BNC, Thermocouple
Operating Temperature 32°F to 105°F (0°C to 40°C)
Power Input USB Type-C adapter input: 100-240 VAC, 50-60 Hz
Rechargeable Battery Li-Ion 14.4V, 49Wh, <10A@ 6.8Ah;
up to 5 hours battery life
Other I/O HDMI, Thermocouple
Temperature Compensation Automatic, thermocouple input
User Interface Portable touchscreen 6.9" (default)
Web browser accessible through ITOP operating platform on any operating system and device
Dimensions 8.3”(W) x 6.9”(D) x 2.3”(H)
210 mm(W) x 176 mm(D) x 67 mm(H)
Weight 2.6lb/1,2Kg (2.1Ib/950g without battery)